A BIPOTENTIOMETRIC FIA SYSTEM FOR DETERMINATION OF VITAMIN C

Harjana ., Imam Siswanto, Muzakki ., Sumardi ., Miftahul Huda

Abstract


A bipotentiometric FIA system has been developed for the determination of vitamin C. The system was a single stream manifold, which consisted of a peristaltic pump, a self made injector with internal loop and two Pt-electrodes connected to a PC by serial ADC or parallel ADC interface card. One of the Ptelectrodes was located in the injector before the internal loop, while the other electrodes at the end of the TEFLON reaction tube. The PC was supported with a self-made software for controlling the pump, signal acquisition, processing, and visualisation, and further peak determination, followed by calibration of standard solutions and calculation of sample concentrations. The above FIA-system configuration was applied to determine vitamin C by the injection of sample solution into a stream of potassium hexacyanoferrate (III) solution. The optimum result was achieved with knitted tube reaction of 0.8 mm i.d., 50 cm length, at flow rate 0,64 ml/minute, and consumed 3.6 ml of carrier solution per five injection, and gave linearity range at 0.001 – 0.100 N vitamin C, with the coefficient of correlation 0.9999, RSD peak to peak better than 3.0% and the error of artificial samples were less than 3.4 %.

Key Words : Bipotentiometric-FIA, injector with internal loop, module-program, vitamin C


Full Text:

Untitled

References


Arya, S.P., Mahajan, M, and Jain, P., 1998, Photometric Methods for the Determination of Vitamin C, Anal. Sci. , 14(5), 889-895

Burger, N.and Gasparec, V.K., 1973, Talanta, 20, 782 in Arya, S.P., Mahajan, M, and Jain, P., 1998, Photometric Methods for the Determination of Vitamin C, Anal. Sci. , 14(5), 889-895

Harjana, Imam Siswanto, Muzakki, Soemardi, Bambang Supriyanto, 1997, PC-titrator : Alternatif teknik analisis ramah lingkungan, Laporan RUT-V tahun I.

Hasebe, T. and Kawashima, T., 1996, Flow Injection Determination of Ascorbic Acid by Iron(III) Catalyzed Lucigenin Chemiluminescence in a Micellar System, Anal. Sci. , 12(5), pp. 773-8

Huang, H., Cai, R., Korenaga, T., Zhang, X., Yang, Y., Du, Y. and Zeng , Y., 1997, Micelle Enhanced Spectrofluorimetric Determination of L-ascorbic, Acid Based on Laccase-linked Coupling Reaction Using Flow-injection Stopped-flow Technique, Anal. Sci. ,. 13(suppl), pp., 67-70

Sano, T. Kuwayama, M. Furukawa, S. Takitani and. Nakamura, H., 1995 , Determination of L-Ascorbic Acid by a Flow Injection Analysis with Copper(II)-Mediated Electrochemical Detection, Anal. Sci., 12(3), pp. 405

Veltsistas, P.G, Sikalos, T.I., Prodromidis, M I., Papadimitriou, C.D., Karayannis, M.I., 2000, Construction of a Triphenyltetrazolium Liquid Membrane Ion Selective Electrode and its Analytical Application to the Assay of Vitamin C, Mikrochim. Acta,. 135(1-2), pp 113-117

Yu, A.M., He, C.X, Zhou, J, Chen, H.Y., 1997, Flow injection analysis of ascorbic acid at a methylene green chemically modified, Mikrochimica Acta, Vol. 357(1), pp 84-85

Zar, J.H., 1974, Biostatistical Analysis, 1rst ed. Prentise Hall, Inc, Sydney, pp. 198-234.




DOI: http://dx.doi.org/10.14499/indonesianjpharm0iss0pp276-283

Refbacks

  • There are currently no refbacks.




Copyright (c) 2017 INDONESIAN JOURNAL OF PHARMACY

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

Indonesian J Pharm indexed by:

web
analytics View My Stats