Utilizing of alkybenzene homologous series on the determination of kovats retention index in the RP-HPLC using methanol/water solvent system

Rinaldi Idroes

Abstract


Retention times in high performance liquid chromatography are very susceptible to small changes of the stationary phase, temperature, pH-value, mobile-phase composition and flow rate. One of the methods to minimize these effects is by utilizing a retention index system. In contrast to GC, the retention Index determination method in HPLC is still widely discussed, because of difficulty utilizing n-alkane as standard. In addition, the solutes in HPLC interact with the mobile-phase, thus the retention data also depend on the mobilephase. It is not easy to use n-alkane in HPLC as standards because of considerable problems. Due to their very non polar properties, hence in most reversed phase systems, they show large retention times. Therefore, using nalkane in routine analysis could be inconvenient. In comparison with n-alkane, the alkylbenzene homologous series are stable compound and commercially available. They have a high UV absorbance at the wavelength of 254 nm, and thus are easily detected by a UV detector. This paper will introduce Kovats Retention Index Determination in the HPLC by using alkylbenzene homologous series and then is to be connected with n-alkane as a frame of reference. Steroids were used as test substance for determining Kovats retention index values in methanol/ water system.

Key words: RP-HPLC, Kovats Retention Index, n-Alkane, Alkyl Benzene.


Full Text:

IJPJune2009_77-83

References


Baker, J.K. and Ma, C.Y. 1979. Retention Index Scale for Liquid-liquid Chromatography, Journal of Chromatography, 169:107.

Bogusz, M. and Aderjan, R.J. 1988. Improved Standardization in Reversed-Phase High Performance Liquid Chromatography Using 1-Nitroalkanes as a Retention Index Scale, Journal of Chromatography, 435:43.

Didaoui, L., Touabet, A., Meklati, B.Y., Lewin-Kretzschmar, U., and Engewald, W. 1996. Comparison of retention indices of some explosives and related compounds calculated by different mathematical methods in reversed-phase liquid chromatography, HRC-Journal of High Resolution Chromatography, 22:613 – 618.

Ettre, L.S. and Meyer, V.R. 2001. 1973 When HPLC was Young, LC-GC Europe, June.

Ettre, L.S., 2003, Retention Index Expressions, Chromatographia 58, October (No. 7/8).

Guardino, X., Albaiges, J., Firpo, G., Rodrigues-Vinals, R., and Gassiot, M. 1976. Accuracy in the Determination of Kovats Retention Index, Journal of Chromatography, 118:13

Harangi, J., 2003, Retention Index Calculation without n-Alkanes – the Virtual Carbon Number, Journal of Chromatography A, 993: 187 – 195.

Horvath, C. 1996. Citius Altius Fortius, LC-GC International, October.

Idroes, R. 2002. Verhalten der Retentionsdaten homologer Reihen als Bezugssystem und zur Vorhersage von Retentionsdaten in der RP-HPLC, Tenea Verlag, Berlin

Kikta, E.J. and Stange, A.E. 1977. Phenones: A Family of Compounds Broadly Applicable to Use as Internal Standards in HPLC. Application to the Analysis of Carbofuran, Journal of Chromatography, 138:41.

Kovats, E., 1958, Gas-chromatographische Charakterisierung organischer Verbindungen, Teil 1: Retentionsindices aliphatischer Halogenide, Alkohole, Aldehyde und Ketone, Helvetica Chemica Acta, Vol XLI, No. 206 (1058) 1915-1932

Kromidas, S. 1999. Validierung in der Analytik, Wiley-VCH Verlag, Weinheim.

Kuronen, K.R. 1991. Use of 1-(p-(2,3-dihydroxypropoxy)Phenyl)-1-alkanones as Retention Index Standards in the Identification of Trichothecenes by Liquid Chromatography- Thermospray and Dynamic Fast Atom Bombardment Mass Spectrometry, Journal of Chromatography, 543:39.

Morishita, F., Kakihana, H., and Kojima, T. 1984. Measurement of Retention Indexes on n- Alkane Scale in Reversed-Phase Liquid Chromatography and their Prediction from Molecular Structures, Analytical Letters, 17 (A20):2385-2398.

Popl, M., Dolansky, V., and Mostecky, J. 1974. Influence of the Molecular Structure of Aromatic Hydrocarbons on their Adsorptivity on Alumina, Journal of Chromatography, 91: 649.

Sachs, L. 1999. Angewandte Statistik, 9. Auflage, Springer Verlag, Berlin.

Waetzig, H. 1989. Reproduzierbarkeit und Vorhersage von Retentionsdaten in der HPLC, Unpublished Ph.D Thesis, Julius Maximillian Universitaet Würzburg, Germany.

Yamauchi, S.J. 1993. Retention Indices of Phenols for Internal Standards in Reversed-Phase High-Performance Liquid Chromatography: Application to Retention Prediction and Selectivities of Mobile Phases and Packing Materials, Journal of Chromatography, 635:61




DOI: http://dx.doi.org/10.14499/indonesianjpharm0iss0pp77-83

Refbacks

  • There are currently no refbacks.




Copyright (c) 2017 INDONESIAN JOURNAL OF PHARMACY

Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.

Indonesian J Pharm indexed by:

web
analytics View My Stats